Production data kit and OEE dashboard
See where production time goes, using data that comes from the machine
Start with a pilot line. Read run, stop and piece-count signals from the existing PLC, let staff pick stop reasons on a tablet, then view shift OEE on a dashboard.

Before the system
Production figures often come from handwriting, so it is hard to say where time is lost
Supervisors total output and stop causes from end-of-shift records. Some periods go unrecorded and some causes are lumped into broad terms, so meetings run on impressions more than data.
OEE can be calculated only when everyone agrees the same definitions: planned time, standard cycle time and scrap. It also depends on which signals the existing PLC can actually provide.

Where the system helps
Read signals from the machine, let people name stop causes, and summarise on a dashboard
The concept image shows a control cabinet with a device linked to the PLC, a packing machine with a tablet beside the line, and a wall dashboard showing run status.
Reading from the PLC is read-only and never commands the machine. Scope is set after a survey, with the customer granting connection access and confirming the definitions used.
How the work flows
- 01
Survey signals and network
Check which signals the PLC gives and how to connect.
- 02
Agree definitions together
Set planned time, standard cycle time and scrap.
- 03
Trial data collection
Collect data and stop causes alongside manual records.
- 04
Compare and accept
Check the data matches, then accept the dashboard.

What the starter set includes
The last item is assessed separately for each job; the others are in the starter set. The actual scope is set out in each project proposal.
- A pilot line or machine chosen together
- Recording run and stop status and piece counts
- Stop reasons logged by staff on a tablet
- Fitting extra counting sensors is assessed separately where no signal exists
Further development, per project
These are directions to assess and test per project. They are not part of the starter set.
Take orders from ERP
Concept · to be assessed- What it does
- Pull production orders and tie them to the running data of each job.
- Benefit
- Results can be viewed clearly for each production order.
- Must pass before use
- The existing ERP's connection must be checked, and an owner agreed for production-order data.
Scrap counts from checkpoints
Concept · to be assessed- What it does
- Bring scrap counts from quality checkpoints into the OEE calculation.
- Benefit
- The overall picture includes quality when the figures match.
- Must pass before use
- Scrap must be defined with the quality team, and someone must confirm the figures taken in.
Energy per unit produced
Concept · to be assessed- What it does
- Compare energy used with pieces produced in each shift.
- Benefit
- Shows the line's energy trend against the work produced.
- Must pass before use
- A reliable power measuring point is needed, and the data's timing must be aligned.
Status lights at the line
Concept · to be assessed- What it does
- Add status lights so run or stop can be seen from a distance.
- Benefit
- Floor staff see status without going up to a screen.
- Must pass before use
- Colour meanings must be agreed with supervisors, and a safe mounting position checked.
Combine lines or plants
Concept · to be assessed- What it does
- Show data from several lines or plants in a single view.
- Benefit
- Running can be compared across lines.
- Must pass before use
- Every line must use the same definitions, and the network between sites must be checked.
Feed a central report system
Concept · to be assessed- What it does
- Send summary data to the reporting system the organisation already uses.
- Benefit
- Production data sits alongside the organisation's reports.
- Must pass before use
- Data format and access permissions must be checked, along with handling of failed transfers.
Comparing ways of working
A comparison of ways of working, not measured before-and-after results.
| Topic | Usual approach | Proposed approach |
|---|---|---|
| Source of data | Handwritten at end of shift | Read from the machine, causes named by staff |
| Stop causes | Lumped into broad terms afterwards | Picked from a list when the stop happens |
| Linking to the PLC | Machine programme edited to pull values | Read-only, confirmed after a survey |
| Daily meeting | Talk from each person's memory | Review the dashboard and daily summary together |
Where it fits
Suits plants that want to know where production time is lost and have a team ready to bring the data to daily meetings.
Limits, and when it does not fit yet
If a machine has no signal and sensors cannot be fitted, or a full MES is wanted from the start, begin by surveying the machine and defining the system's scope.
What to prove before investing
- 01Signals actually readable from the PLC, and access rights
- 02Definitions of planned time, standard cycle time and scrap
- 03System data compared with manual records in the trial
- 04Site network conditions checked as stable enough
FAQ
Frequently asked questions
That cannot be answered before a survey. It depends on whether the PLC already has the signals to read and whether its owner allows it.
No. Reading from the PLC is read-only. The system only displays data, and machine control stays with the existing system.
Extra counting sensors may be fitted but are assessed separately. If they cannot be fitted, this kit may not suit that machine.
What to prepare before talking to us
You do not need all of it; start with what you have.
- A list of the machines to collect data from, with the PLC make and model if you know them.
- Photos of the control cabinets and the site.
- The forms or files you record on today.
- For inspection: sample parts or labels, both passes and fails.
Other products in this group
Cold room and drying room temperature monitoring
Continuous temperature records instead of hand logging, with sensors placed from a room survey
Camera-based part measuring station
Measure repeated parts by camera instead of vernier, once tested on real work
In-line label and packaging inspection
Let a camera help check labels and codes on the line, once tested on real product
Remote pump and tank level monitoring
See pump status and water levels from afar, without driving out on every round
Per-machine and per-line energy metering
See electricity use by machine and by period, instead of one monthly bill total
Send details of your production line to start the signal survey
Tell us the machine type, the PLC used and how stops are recorded now. The team will help define what to survey before choosing the pilot line.