Remote pump and tank level monitoring

See pump status and water levels from afar, without driving out on every round

Start by surveying the pump points, tanks and existing control cabinets, then assess what can really be measured and whether a signal reaches. The system sends pump status, water level and incoming power to a central screen, and alerts when a value leaves the conditions the customer sets.

Discuss remote pump monitoring
Concept rendering: a small pump station beside a concrete tank, a weatherproof control cabinet on a stand, a gateway with an antenna, a small solar panel and a level sensor above the tank
Concept exampleConcept rendering of the system in use. Appearance and configuration depend on the proposed scope.

Before the system

Before the system, you learn a pump stopped or a tank ran low when someone reaches the site

Pump points, sumps and storage tanks are often far from the office or spread over several places, so checks depend on someone driving out on rounds. If a pump stops on a brownout, a protection device trips or the level drops between rounds, it may be found only when the tank is dry or overflowing.

The fix is not simply fitting a sensor and sending values to a phone. Remote sites have weak signal, power cuts and equipment out in sun and rain. A zero reading must be told apart from a device that has stopped reporting, and the customer must agree who goes out when an alert comes in.

Concept rendering: a worker beside a pickup truck on a dirt road, writing on a clipboard in front of a pump house next to a float level gauge on a water tank
Concept exampleConcept rendering of the work on site before the system is in place. Not a photo from a real customer's site.

Where the system helps

The system reports status from remote sites, and separates a fault from lost contact

The concept shows a weatherproof control cabinet beside the pump, a gateway with an antenna, a level sensor in the tank and a central screen showing several sites at once. The gateway keeps data while the signal is down and sends it on when the signal returns.

The project scope sets measurements, alert conditions and recipients with the customer. The starter set watches and alerts. Remote start and stop is an add-on that needs its own safety assessment, and a person still decides when to go out and fix things on site.

How the work flows

  1. 01

    Survey pumps and cabinets

    Review locations, panels, pumps, tanks and the current checks.

  2. 02

    Test signal and measurements

    Measure signal on site and trial reading the pump status.

  3. 03

    Agree the alerts

    Settle conditions, recipients and how lost contact is told apart.

  4. 04

    Accept and rehearse

    Cut the signal and stop a pump to check the alerts are right.

Concept rendering: inside an open weatherproof cabinet, a motor starter, terminal blocks and a rail-mounted gateway with green status lights and an antenna cable
Concept exampleConcept rendering of where the system does its work. Not a photo from a real site. Appearance and configuration depend on the proposed scope.

What the starter set includes

The last item is assessed separately for each job; the others are in the starter set. The actual scope is set out in each project proposal.

  • Pump status signals, such as running, stopped or fault, from the existing cabinet
  • A level sensor in the chosen tank or sump
  • A gateway that keeps data while the signal is down
  • A central screen, alert conditions and a notice when a device loses contact

Further development, per project

These are directions to assess and test per project. They are not part of the starter set.

  • Remote start and stop

    Concept · to be assessed
    What it does
    Add pump start and stop commands to the central screen, confirmed by an authorised person before sending.
    Benefit
    Fewer trips made only to switch a pump.
    Must pass before use
    The pump and pipework must be assessed for safety, the people allowed to send commands defined, and the control wiring connected by the electrician who looks after the cabinet.
  • Motor current monitoring

    Concept · to be assessed
    What it does
    Fit a power meter on the pump motor to see whether its draw leaves the normal range.
    Benefit
    Helps spot signs such as dry running or a blocked impeller before the pump stops.
    Must pass before use
    An electrician must install it, and readings from a trial period form the baseline before thresholds are set.
  • Pipe pressure or flow

    Concept · to be assessed
    What it does
    Add a pressure sensor or flow meter on the delivery pipe.
    Benefit
    Shows when the pump runs but water does not move, such as a leak or a closed valve.
    Must pass before use
    The position must be chosen with whoever looks after the pipework, and supply may need to stop during installation.
  • Backup power and solar

    Concept · to be assessed
    What it does
    Add a backup battery or solar panel for the gateway and sensors.
    Benefit
    The site can still report that mains power failed, instead of going silent with it.
    Must pass before use
    Load and sunlight at the site must be calculated, and the battery checked on a schedule.
  • Escalating alerts

    Concept · to be assessed
    What it does
    Pass an alert to the next person when the first does not respond, following the customer's list.
    Benefit
    Less chance of a night-time alert sitting unanswered.
    Must pass before use
    The list, order and channels must be agreed, and out-of-hours receipt rehearsed before real use.
  • Maintenance log

    Concept · to be assessed
    What it does
    Record each call-out, its cause and parts replaced beside the alert history.
    Benefit
    Shows which sites fail often and why.
    Must pass before use
    Someone must log every call-out. The system only keeps what a person has confirmed.

Comparing ways of working

A comparison of ways of working, not measured before-and-after results.

TopicUsual approachProposed approach
Knowing the statusKnown when someone drives outLatest status on the central screen
When a pump stops or a tank runs lowFound after the effectAlert sent to the named recipient
When the signal dropsNo data for that periodShown as lost contact, held data sent later
Planning call-outsEvery site on the same roundRounds planned with status and history

Where it fits

Suits pumps, sumps or storage tanks that are far away or spread over several sites, where someone is sent out on rounds today.

Limits, and when it does not fit yet

If you want fully automatic pump control from day one, start by designing the control system with whoever runs the water system. If a site has no communication signal at all, the options must be surveyed before scope is agreed.

What to prove before investing

  1. 01Signal tests at the real installation points at different times of day
  2. 02The existing cabinet drawings and where pump status can be taken
  3. 03A comparison of sensor levels against manual readings
  4. 04Who responds, and the steps for an alert or a device that has lost contact

FAQ

Frequently asked questions

What to prepare before talking to us

You do not need all of it; start with what you have.

  • A list of the machines to collect data from, with the PLC make and model if you know them.
  • Photos of the control cabinets and the site.
  • The forms or files you record on today.
  • For inspection: sample parts or labels, both passes and fails.
Fill in the contact form

Send the pump locations and how you check them today

Attach a rough map of the pump points or tanks, photos of the control cabinets, the distance from the office and who should receive alerts. The team will help define which signals and measurements to test before agreeing scope.

Discuss remote pump monitoring