05 · Automation
Machines that act on real signals, in the right order
We design automated sequences from sensors and controllers through to logging. They work with what you already run and stop safely when something goes wrong.
Problems this solves
- 01
Steps that wait for someone to press a button or open a valve stall the line.
- 02
Machines run in isolation and don't pass their status to each other.
- 03
Every product changeover means resetting several machines by hand.
- 04
Machines stop often, with no record of why.
Where it fits
Works well when
- The process is clear and repeatable.
- There is room for added sensors or devices, and access to the control cabinet.
- A maintenance lead knows the current operating sequence.
Limits to know
- Older machines may have no way to read or command them; added sensors or I/O are needed.
- Processes that change constantly may be better served by semi-automation.
- Changes to an existing machine's safety system must involve its maker or responsible engineer.
What we build
01
Control sequences
PLC programs and HMI panels at the machine that define start and stop conditions and how faults are handled.
- The sequence is written down for the production team to confirm before any programming starts.
- Interlocks that stop steps running out of order, and the safe state the machine returns to after a fault.
- HMI screens that show why the machine stopped and what the operator should do next.

Illustration of our approach 02
Sensors and actuators
Selecting and fitting only the detectors, valves, motors or relays the job needs, and a robot arm where a step suits one.

Illustration of our approach 03
Machine-to-machine links
Machines hand status to each other and send data up to monitoring or a database.
- Ready, accept and hold signals between upstream and downstream machines.
- Protocols the machines already support, such as Modbus TCP, EtherNet/IP or CC-Link IE.
- A defined response for each machine when communication drops.

Illustration of our approach 04
Event and stoppage logging
Records when and why a machine stopped, so improvements are based on evidence.
- Time and a reason code for every stop.
- Operators pick the reason from an on-screen list when the machine cannot tell on its own.
- A weekly summary of the most frequent stop reasons, to choose what to fix first.

Illustration of our approach
How it works
Sense → decide → act → log
Automation has to command the machine, know what actually happened and keep a record you can trace.
01
Sense
Sensors read position, level, temperature or whether a part is present.
02
Decide
The controller checks the defined conditions, including fault cases.
03
Act
Motors, valves or reject mechanisms act on the command.
04
Log
Events and measured values are stored and passed to monitoring.
…then back to sensing, every cycle
What we need to start
You don't need all of this before we talk. The discovery stage works out what exists and what is missing.
- A map of the current process, or a site visit by our team.
- Models of the machines and controllers in use, with electrical drawings if available.
- Safety conditions and emergency stops that must be preserved.
- Windows when machines can be stopped for installation and testing.
Testing and acceptance
01
Simulate the sequence before connecting to real machines.
02
Step through on the real machine without product, then run with product.
03
Test faults: a sensor not responding, a jammed part, an emergency stop.
What is delivered
These are the items usually included in this kind of work. The exact scope of each project is set out in the agreed proposal.
- 01Control programs with a written description of the sequence.
- 02Electrical drawings and a list of added equipment.
- 03Test records, including fault cases.
- 04Training for maintenance staff on adjustments and first-line troubleshooting.
Tools and standards we use
Chosen to fit the systems you already run and the budget of each job; no project uses all of them.
- PLC
- Mitsubishi MELSEC iQ-R, Q, FX5U / FX3USiemens S7-1200 / S7-1500Omron NX / NJ, CP1H / CP2EDelta AS300 / AS200, AH500, DVP
- Programming software
- GX Works3 / GX Works2Sysmac StudioCX-ProgrammerISPSoft / WPLSoft
- Robots
- Universal RobotsFANUCABBYaskawaMitsubishi MELFADelta
- Mechanical
- SolidWorksAluminium profile framesServo motorsPneumatics
- Safety
- Safety fences and interlocksLight curtainsArea scannersRisk assessment
- Standards
- IEC 61131-3 (PLC programming languages)ISA-88 (batch control)
FAQ
Frequently asked questions
It depends on whether the machine has a communication port or readable signals. If not, added sensors or I/O modules can usually read its state. We inspect on site before proposing an approach.
Yes, and it's often the better path. Start with the bottleneck or the most error-prone step, then extend once it runs well.
Where appropriate we design a manual mode, and the switch-over procedure is written into the handover documents.
We assess the risks with your team before design, then build in emergency stops, guards, light curtains and interlocks from the start. Safety functions use safety-rated devices rather than relying on ordinary PLC logic alone.
Yes. Program files are handed over with comments and an I/O list as set out in the contract, so your team or another contractor can maintain them.
We prepare and test as much as possible beforehand, with simulation and panel testing, then install during a planned shutdown, with a plan to fall back to the old system if needed.
We work with Mitsubishi, Omron and Delta, and follow the brand your plant already uses so maintenance can support it and spares are easy to find. If your standard is another brand, we can discuss it case by case.
Electrical drawings, the I/O list, an operator manual, and a list of recommended spare parts.
Yes, if your plant's network policy allows. We diagnose over a secure connection first, and come on site when needed.
Further reading
Related articles
Automation14 min readWhat Is OEE? Formula and a Worked Example from a Sample Production LineOEE = Availability × Performance × Quality, a common machine-efficiency metric in factories. This article explains the formula, a step-by-step calculation example, and a commonly cited benchmark with its caveats.
Automation2 min readPLC, ESP32 or Industrial PC: Choosing a Controller from the Real JobPLCs, microcontrollers and industrial PCs each fit different jobs. A data-logging prototype and a machine under continuous control need different I/O, tooling and environmental ratings, so board price is only part of the cost.
Automation2 min readDI, DO, AI and AO: Reading a Machine's I/O ListInputs and outputs are named from the controller's side. DI/DO carry on/off signals or commands; AI/AO carry continuous values within the device's range, such as weight or a control value that needs scaling.
Example problems
Working on something like this?
Tell us your goal and how you work today, and our team will help find the right approach.