06 · SCADA & IoT
See the whole process on one screen
We build monitoring and control systems that collect values from machines and sensors, inside the plant and at distant sites over IoT, show current status, raise alarms when values drift and keep history for analysis.
Problems this solves
- 01
Someone has to walk to each machine to read its values.
- 02
Problems are noticed only after bad product has been made.
- 03
Production data goes onto paper or Excel and can't be compiled in time.
- 04
Each machine vendor has its own screen, so there is no overall view.
- 05
Pumps, cold rooms and distant sites need someone to go and check, and a problem at night goes unnoticed.
Where it fits
Works well when
- Machines, sensors or meters can be read, or can be added.
- You know which values matter and what counts as abnormal.
- There is a site network, or one can be planned.
- You have several branches or sites you want to see together on one screen.
Limits to know
- Remote control of machines needs extra permission and safety design; some sites should monitor only.
- Where the network is unreliable, data must be buffered on site before sending.
- Readings are only as accurate as the sensors; existing calibration should be checked.
What we build
01
Data collection on site
Reads values from controllers (PLCs), power meters and sensors into a central database.

Illustration of our approach 02
IoT and wireless sensors
For points that are hard to wire, far away or spread over many places, such as pumps, cold rooms, tanks, greenhouses or old machines with no data port. Sensors and small data units are added, and their values go into the same system as SCADA.
- Many kinds of reading, such as temperature, humidity, current, vibration, pressure, water level and machine run/stop status.
- Data goes through a gateway over LAN, Wi-Fi or a 4G SIM, whichever the site has, using MQTT, which is light and copes with a connection that drops now and then.
- If the connection drops, the device keeps the readings and sends them once it reconnects, so that period is not lost.
- Devices such as pumps, fans or valves can be switched from the screen or by set conditions, while safety conditions keep running on site.
- Data is kept on your own server or in the cloud, agreed during design.
03
Status screens
Process diagrams, current values and trends, designed around each user's role.
- A plant overview, plus detail pages for each line or machine.
- Colour reserved for abnormal states, so what needs attention stands out.
- Trend charts with a selectable time range and several values side by side.

Illustration of our approach 04
Alarms
Abnormal thresholds, notifications to the responsible person, and acknowledgement records.

Illustration of our approach 05
Reports and data hand-off
Shift or daily summaries such as downtime, OEE and energy use at each metered point, with data passed on to ERP or other systems.
- Formulas such as OEE are agreed with production first, so the numbers match how decisions are made.
- Reports sent automatically by email or viewed on a web page.
- Output counts and downtime passed to the ERP through an API.

Illustration of our approach
How it works
Try the demo dashboards
Sample dashboards on our SCADA system, all running on simulated data. A dashboard loads only when you choose one.
Data path from machine to report
- 01
Sensor
72.4 °C
Mould temperature
- 02
PLC
RUN
Reads it and runs the machine logic
- 03
Gateway
MQTT · every 1 s
Sends values upstream
- 04
SCADA
Alarm above 80 °C
The production team's live screen
- 05
Report / ERP
Totals per shift
The same numbers reach management
Demo dashboards you can open
- 01BTSan • Demo Hub
- 02Plant SCADA
- 03Manufacturing OEE
- 04Water Tank Monitoring
- 05Smart Building
- 06Cold Chain Monitoring
- 07Energy Monitoring
- 08IoT Camera Surveillance
Every dashboard runs on simulated data, not a client's machines, and loads only when you choose it.
Open the SCADA demoWhat we need to start
You don't need all of this before we talk. The discovery stage works out what exists and what is missing.
- A list of machines, sensors and the values to monitor.
- Normal ranges, alarm thresholds and who should be alerted.
- The site network layout, or network and security constraints.
- Examples of the reports you use today.
Testing and acceptance
01
Compare on-screen values with the machine's own display at the same moment.
02
Simulate abnormal values and follow the alarm all the way to the recipient.
03
Cut the connection and confirm no data is lost and it reconnects on its own.
What is delivered
These are the items usually included in this kind of work. The exact scope of each project is set out in the agreed proposal.
- 01Data collection and monitoring screens for the agreed list.
- 02Alarm configuration and user permissions.
- 03The tag list and a connection diagram.
- 04A user guide and instructions for adding new tags.
Tools and standards we use
Chosen to fit the systems you already run and the budget of each job; no project uses all of them.
- SCADA
- AVEVA (Wonderware)IgnitionWinCC
- HMI panels
- Weintek cMT / MTMitsubishi GOT2000Siemens KTP / Comfort PanelPro-face
- Web and mobile dashboards
- Ignition PerspectiveNode-REDGrafanaReact + WebSocket
- Protocols
- Modbus TCP/RTUOPC UAMQTTProfinetEtherNet/IPEtherCATCC-Link IE
- Data and energy metering
- InfluxDB / TimescaleDBThingsBoardPower meters (Modbus)CT / Rogowski coils
- IoT and field devices
- ESP32EMQX / Mosquitto (MQTT broker)IoT gateways over LAN / Wi-Fi / 4GRS-485 sensors (Modbus RTU)LoRaWAN
- Standards
- ISA-101 (HMI design)ISA-18.2 (alarm management)ISA-95 (plant-to-business integration)
FAQ
Frequently asked questions
Yes, if your policy allows it, with user permissions and a secure connection path. Some organisations choose to allow viewing only on the internal network.
Generally yes, depending on how each machine exposes its data. We survey models and ports first, then confirm which points can be read directly and which need added hardware.
No. The demo uses simulated data to show the screen design only, and does not represent any customer's operation.
For example Modbus TCP/RTU, OPC UA, MQTT, Profinet and EtherNet/IP, depending on what each machine supports. Older machines without a comms port can be read through an I/O module or gateway.
On your own server, in a time-series database. How long it is kept depends on what you need and the storage available, and is agreed during design.
Both. Many plants start with monitoring only. Control from SCADA is limited to authorised users with a confirmation step, and safety functions stay at the machine and PLC.
It differs by platform. Some charge by tag count or by the number of viewing clients, some per server, and some tools are open source. We compare them with you before choosing.
Yes. Tag structure and naming are designed so new points or lines can be added. If the platform licenses by tag, we flag the effect before adding.
SCADA usually covers plant machines already wired to PLCs. IoT suits points that are spread out or far away, using small sensors and devices that send data over a network or the internet. Many jobs use both and bring the data onto the same screens.
Usually yes, for example a gateway with a 4G SIM, or a long-range wireless link that gathers several points into one gateway. We check the signal on site first, then propose what suits the area.
It depends on the point. Some take power from an existing control panel; others use battery sensors that report at intervals, which need a battery-change schedule. We explain the trade-offs of each before choosing.
Field devices are designed to keep readings and send them once reconnected, and important control, such as stopping a pump when the water is low, runs on site without waiting for the server. This is tested before handover.
Further reading
Related articles
Smart factory28 min readOPC UA, MQTT and Modbus: Choosing the Communication Layers in a Smart FactoryModbus reads register numbers, OPC UA gives values their meaning, MQTT carries messages upward to many receivers. Three names, three layers. A runnable single-machine example shows what each layer does, with TypeScript, real output and production cautions (Thai text).
Smart factory26 min readCollecting data from an old machine with no network port: CT clamp, count pulses and MQTT that survives network dropsReading run/idle/off from motor current, counting parts from a bouncy pulse input, summarising in time windows and publishing over MQTT with store-and-forward, with runnable TypeScript, real output and electrical-safety notes (Thai text).
Smart factory7 min readCapturing Downtime Reasons So They Actually Help Fix ProblemsKnowing how many minutes a machine stopped is not enough. This covers designing short, non-overlapping reason codes that people can really fill in on the floor.
Example problems
Working on something like this?
Tell us your goal and how you work today, and our team will help find the right approach.