6 min read · Smart factory

When a machine is not producing, people tend to assume it is not using power. In fact heaters hold temperature, hydraulic pumps keep turning, compressors run unloaded, and cooling fans never stop. This power is called standby (or idle) energy.
Added up over a whole night and a whole month it can be significant. But unless you measure it by state, you cannot see it, because it is buried in the plant's total electricity bill. The example here is hypothetical.
Why separate by machine state
The monthly total bill cannot tell you which machine uses power when. If you record power together with machine state, such as producing, waiting, stopped for repair and off-shift, you can see how much power the waiting state draws and how many hours a day it lasts.
State data may come from a signal tower light, a part counter, or the stop reason selected by the operator. See the guidance in the articles on downtime reason codes and measuring energy per unit produced.
How to measure, step by step
- Install a power meter at the machine's electrical cabinet or on the chosen feeder. Have a licensed electrician do the installation.
- Set the reading of power in kilowatts (kW) frequently enough to see the heater's duty cycle, for example once a minute.
- Take the machine state from the signal tower or the PLC and record it against the same timestamp.
- Check that the meter's clock and the system's clock match; otherwise state and power will be offset.
- Collect data for at least one week that includes both working days and days off.
- Calculate energy by state: power multiplied by hours in each state, summed.
- Review it together with the machine operators and maintenance, to decide what can be switched off and what must stay on.
| What is checked | How | Who does it | Caution |
|---|---|---|---|
| Power while waiting | Read the value while the machine is in the waiting state | Electrician and production | Heaters cycle on and off, so look at the average over several cycles |
| Hours in each state | Sum up from the recorded states | Data collection system | Periods with missing data must not be counted as waiting |
| Items that can be switched off | Go through the equipment list item by item | Maintenance and the machine manufacturer | Some items need a long warm-up before reuse once switched off |
| Result after the change | Measure again with the same method | Electrician and production | Compare the same time period and conditions |
What can be switched off, and what should not be
Not everything can be switched off. Some heater groups must hold temperature, otherwise the next job waits a long time to start or parts are damaged. Some pumps must keep turning to maintain pressure or lubrication. Always ask the machine manufacturer or maintenance first.
A safer option than switching off completely is usually to step down, for example lowering the holding temperature, or putting the pump into an economy mode when there has been no work for longer than a set time. This must be tested before real use.
Common mistakes
- Measuring only during production and concluding that waiting time does not matter.
- Switching equipment off to save power without asking the machine manufacturer, damaging the machine or delaying restart.
- Using a guessed price per kWh instead of the rate on the actual bill.
- Not measuring again after changing the way of working, so you never know whether it worked.
Hypothetical example: one injection moulding machine
Suppose one machine draws 3.2 kW while waiting, which happens an average of 14 hours a day, on 26 working days a month (all numbers hypothetical).
- Before: 3.2 kW × 14 hours = 44.8 kWh a day × 26 days = 1,164.8 kWh a month. At an assumed rate of THB 4.5 per kWh, that is about THB 5,242 a month.
- After: the team agrees to switch off some heating zones and lower the holding temperature. Waiting power drops to 1.1 kW × 14 hours = 15.4 kWh a day × 26 days = 400.4 kWh a month, about THB 1,802.
- The difference is 1,164.8 − 400.4 = 764.4 kWh a month, about THB 3,440 a month at the same rate.
This figure helps decide whether it is worth continuing, but it must be weighed against the time the machine needs to warm up again and the quality of parts at the start of the shift.
Limitations and cautions
All numbers in the example, including 3.2 kW, 1.1 kW, 14 hours, 26 days and THB 4.5 per kWh, are hypothetical and do not come from a real machine. Actual savings depend on the machine, the process and each site's electricity rate, and may not match the calculation.
Installing a meter connected to the electrical system must be done by a licensed technician in line with the plant's safety standards. Changing how equipment is switched off or reduced must be agreed with the machine manufacturer or maintenance.