7 min read · Machine vision

A single part has many faces: top, sides, bottom and inside holes. But one camera can only see some of them at a time. If this is not thought through from the start, the system judges pass or fail from what it can see only, and the parts it cannot see are checked by no one. The examples in this article are hypothetical.
What is a blind spot?
A blind spot is the part of a workpiece that the inspection system cannot see at all, or cannot see clearly enough to judge. It may come from the camera angle, the part hiding itself, shadows from the lighting, or areas covered by the fixture or the belt. A blind spot is not always a flaw, if the team knows it exists and controls that area by other means. If nobody knows, it becomes a gap through which defects can slip.
Options for seeing several faces
| Method | Advantages | What to watch for |
|---|---|---|
| Add cameras | See several faces at once, no extra time | Cost and image synchronization, calibration of each camera, and the lighting angle for each |
| Use mirrors | One camera sees another face, economical | The longer optical path changes focus and image size; mirrors can get dirty or tilt and need cleaning |
| Rotate or flip the part | One camera checks several faces one at a time | Adds cycle time, positioning must be repeatable, and the mechanism may mark the part |
| Move the camera, for example on a robot arm | Flexible, adaptable to different part types | Complex, needs consistent position calibration, and takes time |
| A gap in the belt for the underside | See the underside without flipping | Dirt or glass under the belt; small parts can fall through the gap |
For choosing lenses and setting the distance for each camera, see the article on lenses, resolution and field of view. For the lighting angle for each side, see the article on choosing lighting for vision inspection.
Map the blind spots on purpose
- List every face and point of the part that must be inspected, for example top face, edges, holes, welds, underside, inside of holes.
- Look at the defect history to see which points defects occur at most often, and give those points priority.
- Try the proposed camera position and photograph real parts, both good and defective, at that position.
- Have people look at the images and decide whether each type of defect is visible clearly enough to judge, then record in a table whether each point is fully, partly or not visible.
- Adjust the position, or add a camera, mirror or rotation mechanism, then fill in the table again.
- For points that are still not visible, decide whether that is acceptable. If it is, there must be another control to cover it, such as sampling checks by people, and write it down.
The coverage table
A coverage table gives the overall picture. Each row is an inspection point and each column is a camera or viewing method. Each cell says whether the point is fully seen, partly seen or not seen. With it you can see at once which points no camera sees, and what adding one camera or mirror would help with.
Common mistakes
- Placing the camera where it is convenient to install, instead of where the inspection points require.
- Testing with defective parts whose marks are in an angle the camera already sees.
- Using a mirror without thinking about focus distance and cleanliness.
- Not calibrating several cameras to each other, so images cannot be compared or measured across.
- Not writing down which points are blind spots, so later users assume the system checks every face.
- Adding several cameras without synchronizing them, so they shoot at different moments and the images do not match the same part.
Hypothetical example: inspecting a metal bracket
Suppose a metal bracket has 8 points to inspect: a hole on the top face, scratches on the top face, the front edge, the rear edge, the left weld, the right weld, the underside, and the inside of the drilled hole. The team starts with one camera above. The result is that 2 points are fully visible (the hole and the scratches on the top face), 2 are partly visible (front edge and rear edge), and 4 are not visible at all (both welds, the underside and the inside of the drilled hole). That is 2 + 2 + 4 = 8 points.
The team adds one camera under the part through a gap in the belt, and two mirrors to show the two welds. The new result is 5 points fully visible (the hole and scratches on the top face, both welds and the underside), 3 partly visible (front edge, rear edge and inside of the drilled hole), and none that is not visible at all. That is 5 + 3 = 8 points.
The team also records the 3 partly visible points as limits of the system and has staff check those points by hand on a sampling schedule. The team still has to test with defective parts whose marks are really at those points, because being able to see the image does not mean the AI can always catch the mark.
Limits and cautions
Adding cameras and mirrors adds cost, complexity and maintenance work, and some points, such as the inside of deep holes or subsurface marks, may not be inspectable with an ordinary camera and need other methods, such as 3D inspection or another kind of inspection, which are outside the scope of this article. The blind-spot map must be reviewed whenever the part, the fixture or the lighting changes. The figures in the example, such as 8 points, 5 points and 3 points, are all hypothetical. Deciding which blind spots are acceptable must be done by the quality department and the responsible people according to the product’s risk.
Starting references
- Wikipedia — Machine vision
- Wikipedia — Automated optical inspection
- Wikipedia — Telecentric lens